MR-96 Microplate Reader

Features

    An 8-channel microplate reader with high sophisticated technology
    High quality, high reliability and easy to operate
    Automatic focusing function makes the testing results more precise
    Tray shaking function

    Technical Specifications

    Measuring System: 8 channels
    Wavelength: 405/450/492/630nm
    Linear Measurement Range: 0.001-3.500 Abs
    Photometric Accuracy: ?.02 A
    Repeatability: <0?.0%
    Stability: <0.005 Abs
    Tray Shaking: Yes
    Optical Filters: 578,620nm
    Detector: Automatic focusing function makes the results more precise.
    Interface: RS232 serial port
    Printer: Internal printer
    Analysis Mode: O.D.,cut-off, single and multi-standard(up to 10 calibrators), Mono-bichromatic wavelength, dynamic reading, etc.
    Data processing and memorization: The reader has the function to store
    Test methods. In addition, MR-96 is also able to memorize 200 tests and 1500 tests separately.
    Power Supply: 220V 50HZ

Download Bronchure

MP-10/50/200/1000 Variable Volume Micropipette

  • MP-10: 0.5–10μl (0.1μl /step)
  • MP-50: 10–50μl (0.1μl /step)
  • MP-200: 20–200μl (0.5μl /step)
  • MP-1000: 100–1000μl (1.0μl /step)

 

 

 

Download Bronchure

SA-20 Semi-Automatic Biochemistry Analyzer

Features

•    End point, kinetic, fixed time, mutistandard, bichromatic etc
•    Filter wavelengths: 7standard filters from 340 to 800nm, 2 more open filter positions, others are available on request
•    With 20 incubating positions
•    Large memory to store 200 test programs and 1000 testing results
•    Excellent Q.C function Q.C. chart can be stored, displayed and printed.

Technical Features

•    Reading Cuvette: Both through cell and direct reading cuvette
•    Incubating Positions: 20 incubation positions
•    Photometric System:
Light Source: 6V 10W long-life halogen lamp
Filters: 7standard filters from 340 to 800nm, 2 more open filter positions; ±2 nm pass-band
Wavelength Accuracy: ±2 nm
•    Measuring System: Measuring Range: 0-3.500 O.D
Photometric Linearity: ±2% from 0 to 2.000 O.D.
Photometric Accuracy: ±2% from 0 to 2.000 O.D.
Drift: less than 0.001 O.D.
Carry Over: ≤1%
•    Incubator Temperature control: 25degree.centigrade ,30degree.centigrade ,37degree.centigrade, Precision:±0.1degree.centigrade
•    Reagent Volume: 200-500 ul
•    Printer: Built-in thermal printer, 57mm width paper
•    Power Supply: 110V 60HZ / 220V 50HZ, 60VA
•    Dimensions: 34cm*38cm*18cm
•    Weight: 8.5kg

Download Bronchure

EA-2/3/5 Electrolyte Analyzer

Features

    Friendly software makes it easy to operate
    Automatic priming and maintenance minimize problems
    Automatic probe cleaning, reducing carry-over
    Automatic standby mode makes it ready to work immediately at any time
    Automatic calibration
    Long-life and stable electrodes

    Technical Specifications

    Parameter: EA-2 : K+ Na+ ,EA-3 : K+ Na+ Cl- ,EA-5 : K+ Na+ Cl- Ca2+ PH
    Assay Method: Ion selective electrode
    Throughput: 60 samples/ hr
    Data Storage: More than 2000 samples and Q.C. data
    Sample Type: Whole blood, serum, plasma or urine
    Sample Volume: 120 ul
    Display: 128 mm*64mm back-illuminated LCD
    Printer: Built-in thermal printer, 58 mm width paper
    Output: RS-232
    Environment requirements: Temperature:18-35degree.centigrade, humidity:=85%
    Power Supply: AC 110V 60HZ, 50W / 220V 50HZ
    Dimension: 30cm*25cm*24cm
    Weight: 7.0kg

Download Bronchure

CA-02 Double Channel Coagulometer

Features

    Friendly software makes it easy to operate
    Automatic stirring system
    Accurate measurement, no influence from pathological sample during the test
    The results are both printed and displayed in second and in concentration. PT data are printed with RATIO AND INR value, all program are stored with personalized parameters.
    Open system for reagent, low reagent consumption(50-100ul)
    Automatic storage, printout calculation parameter curve.

    Technical Specifications

    Channel: Double
    Built-in Incubator: 37degree.centigrade ?.3degree.centigrade,capacity for 2 *16 positions and 2*2 reagent positions
    Measuring System: Photometric
    Beam Source: LED
    Magnetic Stirring Motor: For measuring cuvette
    Data input: Membrane keypad
    Display: Back-illuminated LCD
    Printer: Built-in thermal printer, 58mm width paper
    Operation Language: English, other language are available on request
    Power Supply: 110V 60HZ / 220V 50HZ
    Dimension: 30cm*40cm*15cm